Version: V1.1Release Date: 2022-01-20


PP20x-D1
Vendor ID 350 (0x015e) Vendor Logo
Vendor Name Baumer Electric AG
Vendor Text www.baumer.com
Vendor URL http://www.baumer.com
Device ID 50013 (0x00c35d)
DeviceFamily PP20x
Features
Block Parameter yes
Data Storage yes
Profile Characteristic 0x0001 (Device Profile: Generic Profiled Sensor), 0x000a (Device Profile: Measuring Sensor), 0x8001 (Function Class: Multiple switching signal)
Supported Access Locks Parameter: no, Data Storage: yes, Local Parameterization: no, Local User Interface: no
Communication
IO-Link Revision V1.1
Transmission Rate38400 bit/s (COM2)
Minimum Cycle Time 5 ms
SIO Mode Supported yes
M-Sequence CapabilityPREOPERATE = TYPE_1_V with 8 octets on-request data
OPERATE = TYPE_2_V with 8 octets on-request data
ISDU supported
Device Variant PP20H-x.xxxxx.D1xx.xxxxxx.xx0
Description Pressure measurement for hygienic applications
Product ID PP20H-x.xxxxx.D1xx.xxxxxx.xx0
Device Icon Device Icon
Device Symbol Device Symbol
Connection TypeNon-standard connector
Connection Symbol Connection Symbol
Connection Description M12 connector
- pin 1 brown; L+; +Vs
- pin 2 white; Other; Iout
- pin 3 (light) blue; L-; GND (0V)
- pin 4 black; C/Q; SW1
- pin 5 grey (slate); NC; N.C.
Device Variant PP20S-x.xxxxx.D1xx.xxxxxx.xx0
Description Pressure measurement for industrial applications
Product ID PP20S-x.xxxxx.D1xx.xxxxxx.xx0
Device Icon Device Icon
Device Symbol Device Symbol
Connection TypeNon-standard connector
Connection Symbol Connection Symbol
Connection Description M12 connector
- pin 1 brown; L+; +Vs
- pin 2 white; Other; Iout
- pin 3 (light) blue; L-; GND (0V)
- pin 4 black; C/Q; SW1
- pin 5 grey (slate); NC; N.C.

ProcessData id=P_PdPressurePa0 (condition V_DisplayControlValues.Selected PV = 64)

ProcessDataIn "Pressure Data In" id=P_PdInPressurePa0

bit length: 32
data type: 32-bit Record

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 16-bit Integer Pressure
2 8 8-bit Integer Pressure Scale Exponent
3 7 Boolean SSC6 / Not used
4 3 Boolean Alarm / General
5 1 Boolean SSC2 / Process Temperature
6 0 Boolean SSC1 / Pressure
Octet 0
bit offset 31 30 29 28 27 26 25 24
subindex 1
element bit 15 14 13 12 11 10 9 8
Octet 1
bit offset 23 22 21 20 19 18 17 16
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 2
bit offset 15 14 13 12 11 10 9 8
subindex 2
element bit 7 6 5 4 3 2 1 0
Octet 3
bit offset 7 6 5 4 3 2 1 0
subindex 3 / / / / / / / / / / / / / / / / / / 4 / / / / / / 5 6

ProcessData id=P_PdPressurePaP1 (condition V_DisplayControlValues.Selected PV = 65)

ProcessDataIn "Pressure Data In" id=P_PdInPressurePaP1

bit length: 32
data type: 32-bit Record

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 16-bit Integer Pressure
2 8 8-bit Integer Pressure Scale Exponent
3 7 Boolean SSC6 / Not used
4 3 Boolean Alarm / General
5 1 Boolean SSC2 / Process Temperature
6 0 Boolean SSC1 / Pressure
Octet 0
bit offset 31 30 29 28 27 26 25 24
subindex 1
element bit 15 14 13 12 11 10 9 8
Octet 1
bit offset 23 22 21 20 19 18 17 16
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 2
bit offset 15 14 13 12 11 10 9 8
subindex 2
element bit 7 6 5 4 3 2 1 0
Octet 3
bit offset 7 6 5 4 3 2 1 0
subindex 3 / / / / / / / / / / / / / / / / / / 4 / / / / / / 5 6

ProcessData id=P_PdPressurePaP2 (condition V_DisplayControlValues.Selected PV = 66)

ProcessDataIn "Pressure Data In" id=P_PdInPressurePaP2

bit length: 32
data type: 32-bit Record

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 16-bit Integer Pressure
2 8 8-bit Integer Pressure Scale Exponent
3 7 Boolean SSC6 / Not used
4 3 Boolean Alarm / General
5 1 Boolean SSC2 / Process Temperature
6 0 Boolean SSC1 / Pressure
Octet 0
bit offset 31 30 29 28 27 26 25 24
subindex 1
element bit 15 14 13 12 11 10 9 8
Octet 1
bit offset 23 22 21 20 19 18 17 16
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 2
bit offset 15 14 13 12 11 10 9 8
subindex 2
element bit 7 6 5 4 3 2 1 0
Octet 3
bit offset 7 6 5 4 3 2 1 0
subindex 3 / / / / / / / / / / / / / / / / / / 4 / / / / / / 5 6

ProcessData id=P_PdPressurePaP3 (condition V_DisplayControlValues.Selected PV = 67)

ProcessDataIn "Pressure Data In" id=P_PdInPressurePaP3

bit length: 32
data type: 32-bit Record

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 16-bit Integer Pressure
2 8 8-bit Integer Pressure Scale Exponent
3 7 Boolean SSC6 / Not used
4 3 Boolean Alarm / General
5 1 Boolean SSC2 / Process Temperature
6 0 Boolean SSC1 / Pressure
Octet 0
bit offset 31 30 29 28 27 26 25 24
subindex 1
element bit 15 14 13 12 11 10 9 8
Octet 1
bit offset 23 22 21 20 19 18 17 16
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 2
bit offset 15 14 13 12 11 10 9 8
subindex 2
element bit 7 6 5 4 3 2 1 0
Octet 3
bit offset 7 6 5 4 3 2 1 0
subindex 3 / / / / / / / / / / / / / / / / / / 4 / / / / / / 5 6

ProcessData id=P_PdPressurePaP4 (condition V_DisplayControlValues.Selected PV = 68)

ProcessDataIn "Pressure Data In" id=P_PdInPressurePaP4

bit length: 32
data type: 32-bit Record

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 16-bit Integer Pressure
2 8 8-bit Integer Pressure Scale Exponent
3 7 Boolean SSC6 / Not used
4 3 Boolean Alarm / General
5 1 Boolean SSC2 / Process Temperature
6 0 Boolean SSC1 / Pressure
Octet 0
bit offset 31 30 29 28 27 26 25 24
subindex 1
element bit 15 14 13 12 11 10 9 8
Octet 1
bit offset 23 22 21 20 19 18 17 16
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 2
bit offset 15 14 13 12 11 10 9 8
subindex 2
element bit 7 6 5 4 3 2 1 0
Octet 3
bit offset 7 6 5 4 3 2 1 0
subindex 3 / / / / / / / / / / / / / / / / / / 4 / / / / / / 5 6

ProcessData id=P_PdProcessTemperatureCM1 (condition V_DisplayControlValues.Selected PV = 143)

ProcessDataIn "Process Temperature Data In" id=P_PdInProcessTemperatureCM1

bit length: 32
data type: 32-bit Record

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 16-bit Integer Process Temperature
2 8 8-bit Integer Process Temperature Scale Exponent
3 7 Boolean SSC6 / Not used
4 3 Boolean Alarm / General
5 1 Boolean SSC2 / Process Temperature
6 0 Boolean SSC1 / Pressure
Octet 0
bit offset 31 30 29 28 27 26 25 24
subindex 1
element bit 15 14 13 12 11 10 9 8
Octet 1
bit offset 23 22 21 20 19 18 17 16
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 2
bit offset 15 14 13 12 11 10 9 8
subindex 2
element bit 7 6 5 4 3 2 1 0
Octet 3
bit offset 7 6 5 4 3 2 1 0
subindex 3 / / / / / / / / / / / / / / / / / / 4 / / / / / / 5 6

Standard Variable "Direct Parameters - Page 1" index=0 id=V_DirectParameters_1

description: Comprises the required parameters defining the communication characteristics and identifiers for device validation.
data type: 128-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 120 8-bit UInteger ro Reserved
2 112 8-bit UInteger ro Master Cycle Time Communication: Current communication cycle duration used by the master. This value defines the process data cycle.
3 104 8-bit UInteger ro Min Cycle Time Communication: Minimum communication cycle duration supported by the device. This value defines the lowest possible process data cycle.
4 96 8-bit UInteger ro M-Sequence Capability Communication: Information on the structure and the supported features of the communication messages.
5 88 8-bit UInteger 17 ro IO-Link Revision ID Communication: Identifier for the currently used communication protocol revision.
6 80 8-bit UInteger ro Process Data Input Length Communication: Information on width and features of the process input data (Process Data from Device to Master).
7 72 8-bit UInteger ro Process Data Output Length Communication: Information on width of the process output data (Process Data from Master to Device).
8 64 8-bit UInteger ro Vendor ID 1 Identification: Highest octet of the Vendor ID. Combined with the parameter Vendor ID 2, this parameter defines the 16-bit value of the unique Vendor ID as assigned by the IO-Link Community.
9 56 8-bit UInteger ro Vendor ID 2 Identification: Lowest octet of the Vendor ID. Combined with the parameter Vendor ID 1, this parameter defines the 16-bit value of the unique Vendor ID as assigned by the IO-Link Community.
10 48 8-bit UInteger ro Device ID 1 Identification: Highest octet of the Device ID. Combined with the parameters Device ID 2 and 3, this parameter defines the 24-bit value of the vendor-specific Device ID.
11 40 8-bit UInteger ro Device ID 2 Identification: Middle octet of the Device ID. Combined with the parameters Device ID 1 and 3, this parameter defines the 24-bit value of the vendor-specific Device ID.
12 32 8-bit UInteger ro Device ID 3 Identification: Lowest octet of the Device ID. Combined with the parameters Device ID 1 and 2, this parameter defines the 24-bit value of the vendor-specific Device ID.
13 24 8-bit UInteger ro Reserved
14 16 8-bit UInteger ro Reserved
15 8 8-bit UInteger ro Reserved
16 0 8-bit UInteger wo X System Command Application: Command interface for devices without ISDU support. Validity and execution of commands are not confirmed.

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 1 2 3 4 5 6 7 8
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 9 10 11 12 13 14 15 16
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

Standard Variable "Direct Parameters - Page 2" index=1 id=V_DirectParameters_2

description: A set of parameters for devices without ISDU support.
data type: 128-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 120 8-bit UInteger Device-specific Parameter 1
2 112 8-bit UInteger Device-specific Parameter 2
3 104 8-bit UInteger Device-specific Parameter 3
4 96 8-bit UInteger Device-specific Parameter 4
5 88 8-bit UInteger Device-specific Parameter 5
6 80 8-bit UInteger Device-specific Parameter 6
7 72 8-bit UInteger Device-specific Parameter 7
8 64 8-bit UInteger Device-specific Parameter 8
9 56 8-bit UInteger Device-specific Parameter 9
10 48 8-bit UInteger Device-specific Parameter 10
11 40 8-bit UInteger Device-specific Parameter 11
12 32 8-bit UInteger Device-specific Parameter 12
13 24 8-bit UInteger Device-specific Parameter 13
14 16 8-bit UInteger Device-specific Parameter 14
15 8 8-bit UInteger Device-specific Parameter 15
16 0 8-bit UInteger Device-specific Parameter 16

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 1 2 3 4 5 6 7 8
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 9 10 11 12 13 14 15 16
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

Standard Variable "System Command" index=2 id=V_SystemCommand

description: Command interface for applications. A positive acknowledge indicates the complete and correct finalization of the requested function.
data type: 8-bit UInteger
allowed values: 130 = Restore Factory Settings
access rights: wo
modifies other variables

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Standard Variable "Device Access Locks" index=12 id=V_DeviceAccessLocks

description: The access to the device parameters can be restricted by setting appropriate flags within this parameter.
data type: 16-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Boolean false = Unlocked, true = Locked Parameter Write Access This lock prevents the write access to all read/write parameters of the device except for the parameter 'Device Access Locks'.
2 1 Boolean false = Unlocked, true = Locked false Data Storage This lock prevents the write access to the device parameters via the data storage mechanism.
3 2 Boolean false = Unlocked, true = Locked Local Parameterization This lock prevents the device settings from being changed via local operating elements on the device.
4 3 Boolean false = Unlocked, true = Locked Local User Interface This lock prevents the access to the device settings and display via a local user interface. The user interface is disabled.
Octet 0
bit offset 15 14 13 12 11 10 9 8
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
Octet 1
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / 4 3 2 1

Standard Variable "Vendor Name" index=16 id=V_VendorName

description: The vendor name that is assigned to a Vendor ID.
data type: 32-octet String UTF-8
default value: "Baumer Electric AG"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Vendor Text" index=17 id=V_VendorText

description: Additional information about the vendor.
data type: 32-octet String UTF-8
default value: "www.baumer.com"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Product Name" index=18 id=V_ProductName

description: Complete product name.
data type: 32-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Product ID" index=19 id=V_ProductID

description: Vendor-specific product or type identification (e.g., item number or model number).
data type: 32-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Product Text" index=20 id=V_ProductText

description: Additional product information for the device.
data type: 64-octet String UTF-8
default value: "Pressure Sensor"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Serial Number" index=21 id=V_SerialNumber

description: Unique, vendor-specific identifier of the individual device.
data type: 16-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Hardware Revision" index=22 id=V_HardwareRevision

description: Unique, vendor-specific identifier of the hardware revision of the individual device.
data type: 12-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32

octet 8 9 10 11  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  

Standard Variable "Firmware Revision" index=23 id=V_FirmwareRevision

description: Unique, vendor-specific identifier of the firmware revision of the individual device.
data type: 12-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32

octet 8 9 10 11  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  

Standard Variable "Application-specific Tag" index=24 id=V_ApplicationSpecificTag

description: Possibility to mark a device with user- or application-specific information.
data type: 32-octet String UTF-8
default value: "***"
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Device Status" index=36 id=V_DeviceStatus

description: Indicator for the current device condition and diagnosis state.
data type: 8-bit UInteger
allowed values: 0 = Device is OK, 1 = Maintenance required, 2 = Out of specification, 3 = Functional check, 4 = Failure
access rights: ro
dynamic

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Standard Variable "Detailed Device Status" index=37 id=V_DetailedDeviceStatus

description: List of all currently pending events in the device.
data type: Array[1] of 3-octet OctetString (subindex access not supported)
access rights: ro
dynamic

octet 0 1 2  
bit offset 23 - 16 15 - 8 7 - 0  
subindex 1 1 1  

Variable "Function Tag" index=25 id=V_FunctionTag

data type: 32-octet String UTF-8
default value: "***"
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Location Tag" index=26 id=V_LocationTag

data type: 32-octet String UTF-8
default value: "***"
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "SSC1 Parameter" index=60 id=V_SSC1_Param

data type: 64-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 32 32-bit Integer 0 Setpoint 1 Value 1, where the SSC1 changes.
2 0 32-bit Integer 0 Setpoint 2 Value 2, where the SSC1 changes.

octet 0 1 2 3 4 5 6 7
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "SSC1 Configuration" index=61 id=V_SSC1_Config

data type: 16-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 8 8-bit UInteger 0 = Normal, 1 = Inverted 0 Logic SSC1 logic, concerning the output signal.
2 0 8-bit UInteger 3 = Two Point 3 ro Mode SSC1 mode, appropriate the IO-Link standard definitions.

octet 0 1  
bit offset 15 - 8 7 - 0  
subindex 1 2  
element bit 7 - 0 7 - 0  

Variable "SSC2 Parameter" index=62 id=V_SSC2_Param

data type: 64-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 32 32-bit Integer 0 Setpoint 1 Value 1, where the SSC2 changes.
2 0 32-bit Integer 0 Setpoint 2 Value 2, where the SSC2 changes.

octet 0 1 2 3 4 5 6 7
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "SSC2 Configuration" index=63 id=V_SSC2_Config

data type: 8-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
2 0 8-bit UInteger 3 = Two Point 3 Mode SSC2 mode, appropriate the IO-Link standard definitions.

octet 0  
bit offset 7 - 0  
subindex 2  
element bit 7 - 0  

Variable "MDC Selection" index=83 id=V_MDCSelection

data type: 8-bit Record
access rights: rw
modifies other variables

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 8-bit UInteger 1 = Pressure, 2 = Process Temperature 1 Source Process value that is shown on the MDC channel.

octet 0  
bit offset 7 - 0  
subindex 1  
element bit 7 - 0  

Variable "Part Number" index=86 id=V_PartNumber

data type: 16-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Process Value Offset" index=105 id=V_ProcessValueOffset

data type: 32-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 16-bit Integer 0 Pressure Offset for the pressure process value, e.g. to correct the impact of the mounting position on the measurement value.
11 0 16-bit Integer 0 Process Temperature Offset for the process temperature process value, e.g. to correct the impact of external temperatures on the measurement value.

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 11 11  
element bit 15 - 8 7 - 0 15 - 8 7 - 0  

Variable "SSC2 Analog Output" index=116 id=V_AnalogOutputSettings

data type: 32-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
3 0 Float32 0.0 State Signal Signal level of the analog output if no valid signal can be shown e.g. because of a too high process temperature.

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 3 3 3 3  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Device Temperature" index=208 id=V_DeviceTemperature

data type: 32-bit Record
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Float32 0.0 Current Internal temperature of the sensor.

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 1  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "CPU Temperature" index=209 id=V_CpuTemperature

data type: 32-bit Record
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Float32 0.0 Current Internal temperature of the CPU.

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 1  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Supply Voltage" index=210 id=V_SupplyVoltage

data type: 32-bit Record
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Float32 0.0 Current Supply voltage of the sensor.

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 1  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Operation Time" index=211 id=V_OperationTime

data type: 32-bit Record
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit UInteger 0 Power-up Operation time since power-up.

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 1  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Process Temperature" index=214 id=V_ProcessTemperature

data type: 32-bit Record
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Float32 0.0 Current Temperature on the measurement membrane.

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 1  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Ambient Pressure" index=215 id=V_AmbientPressure

data type: 32-bit Record
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Float32 0.0 Current Ambient pressure around the sensor.

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 1  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Data for external Applications" index=1024 id=V_DisplayControlValues

data type: 24-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 8-bit UInteger 64 = Pressure / Pascal / 0, 65 = Pressure / Pascal / 1, 66 = Pressure / Pascal / 2, 67 = Pressure / Pascal / 3, 68 = Pressure / Pascal / 4, 143 = Process Temperature / Celsius / -1 64 Selected PV Selected Process Value / Unit / Scale Exponent
2 8 8-bit UInteger 0 = Pascal / 0, 1 = Pascal / 1, 2 = Pascal / 2, 3 = Pascal / 3, 4 = Pascal / 4 0 PV "Pressure" Unit / Scale Exponent
3 0 8-bit UInteger 15 = Celsius / -1 15 PV "Process Temperature" Unit / Scale Exponent

octet 0 1 2  
bit offset 23 - 16 15 - 8 7 - 0  
subindex 1 2 3  
element bit 7 - 0 7 - 0 7 - 0  

Variable "MDC Descriptor" index=16512 id=V_MDC_Descriptor

data type: 88-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 56 32-bit Integer 0 Lower Limit Lower value of the measuring range.
2 24 32-bit Integer 0 Upper Limit Upper value of the measuring range.
3 8 16-bit UInteger 1001 = Celsius, 1130 = Pascal 1130 Unit Code Unit of the selected MDC source.
4 0 8-bit Integer 0 Scale Exponent Value of the exponent to the base of ten, applicable to the value of the MDC.

octet 0 1 2 3 4 5 6 7
bit offset 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10  
bit offset 23 - 16 15 - 8 7 - 0  
subindex 3 3 4  
element bit 15 - 8 7 - 0 7 - 0  

Process Data Formatting

Formatting for Process Data id=P_PdInPressurePa0
Subindex 1: * 1 Pa Dec.0
Subindex 2:
Subindex 3:
Subindex 4:
Subindex 5:
Subindex 6:

Formatting for Process Data id=P_PdInPressurePaP1
Subindex 1: * 10 Pa Dec.0
Subindex 2:
Subindex 3:
Subindex 4:
Subindex 5:
Subindex 6:

Formatting for Process Data id=P_PdInPressurePaP2
Subindex 1: * 100 Pa Dec.0
Subindex 2:
Subindex 3:
Subindex 4:
Subindex 5:
Subindex 6:

Formatting for Process Data id=P_PdInPressurePaP3
Subindex 1: * 1000 Pa Dec.0
Subindex 2:
Subindex 3:
Subindex 4:
Subindex 5:
Subindex 6:

Formatting for Process Data id=P_PdInPressurePaP4
Subindex 1: * 10000 Pa Dec.0
Subindex 2:
Subindex 3:
Subindex 4:
Subindex 5:
Subindex 6:

Formatting for Process Data id=P_PdInProcessTemperatureCM1
Subindex 1: * 0.1 °C Dec.1
Subindex 2:
Subindex 3:
Subindex 4:
Subindex 5:
Subindex 6:

Operator Menus

Identification Menu
V_VendorName
V_VendorText
V_ProductName
V_PartNumber
V_ProductID
V_ProductText
V_ApplicationSpecificTag
V_FunctionTag
V_LocationTag
V_SerialNumber
V_FirmwareRevision
V_HardwareRevision

Parameters Menu
Data for external Applications
V_DisplayControlValues.Selected PV
V_DisplayControlValues.PV "Pressure"
V_DisplayControlValues.PV "Process Temperature"

Maintenance Menus

Identification Menu
V_VendorName
V_VendorText
V_ProductName
V_PartNumber
V_ProductID
V_ProductText
V_ApplicationSpecificTag
V_FunctionTag
V_LocationTag
V_SerialNumber
V_FirmwareRevision
V_HardwareRevision

Parameters Menu
Device Settings
V_SystemCommand, Button:=130
V_DeviceAccessLocks
MDC (Measurement Data Channel) Settings
V_MDCSelection.Source
MDC Descriptor
V_MDC_Descriptor
If V_DisplayControlValues.PV "Pressure" = 0:
Offset 1 (Pressure) Settings
V_ProcessValueOffset.Pressure * 1 Pa, Dec.0
If V_DisplayControlValues.PV "Pressure" = 1:
Offset 1 (Pressure) Settings
V_ProcessValueOffset.Pressure * 10 Pa, Dec.0
If V_DisplayControlValues.PV "Pressure" = 2:
Offset 1 (Pressure) Settings
V_ProcessValueOffset.Pressure * 100 Pa, Dec.0
If V_DisplayControlValues.PV "Pressure" = 3:
Offset 1 (Pressure) Settings
V_ProcessValueOffset.Pressure * 1000 Pa, Dec.0
If V_DisplayControlValues.PV "Pressure" = 4:
Offset 1 (Pressure) Settings
V_ProcessValueOffset.Pressure * 10000 Pa, Dec.0
If V_DisplayControlValues.PV "Process Temperature" = 15:
Offset 2 (Process Temperature) Settings
V_ProcessValueOffset.Process Temperature * 0.1 °C, Dec.1
SSC1 (Pressure) Settings
Configuration
V_SSC1_Config.Mode
V_SSC1_Config.Logic
If V_DisplayControlValues.PV "Pressure" = 0:
Setpoints
V_SSC1_Param.Setpoint 1 * 1 Pa, Dec.0
V_SSC1_Param.Setpoint 2 * 1 Pa, Dec.0
If V_DisplayControlValues.PV "Pressure" = 1:
Setpoints
V_SSC1_Param.Setpoint 1 * 10 Pa, Dec.0
V_SSC1_Param.Setpoint 2 * 10 Pa, Dec.0
If V_DisplayControlValues.PV "Pressure" = 2:
Setpoints
V_SSC1_Param.Setpoint 1 * 100 Pa, Dec.0
V_SSC1_Param.Setpoint 2 * 100 Pa, Dec.0
If V_DisplayControlValues.PV "Pressure" = 3:
Setpoints
V_SSC1_Param.Setpoint 1 * 1000 Pa, Dec.0
V_SSC1_Param.Setpoint 2 * 1000 Pa, Dec.0
If V_DisplayControlValues.PV "Pressure" = 4:
Setpoints
V_SSC1_Param.Setpoint 1 * 10000 Pa, Dec.0
V_SSC1_Param.Setpoint 2 * 10000 Pa, Dec.0
SSC2 (Process Temperature) Settings
Configuration
V_SSC2_Config.Mode
If V_DisplayControlValues.PV "Process Temperature" = 15:
Setpoints
V_SSC2_Param.Setpoint 1 * 0.1 °C, Dec.1
V_SSC2_Param.Setpoint 2 * 0.1 °C, Dec.1
Analog Output
V_AnalogOutputSettings.State Signal * 1 mA, Dec.1
Data for external Applications
V_DisplayControlValues.Selected PV
V_DisplayControlValues.PV "Pressure"
V_DisplayControlValues.PV "Process Temperature"

Diagnosis Menu
V_DeviceStatus
Detailed Device Status
V_DetailedDeviceStatus
Device Temperature
V_DeviceTemperature.Current °C, Dec.1
CPU Temperature
V_CpuTemperature.Current °C, Dec.1
Process Temperature
V_ProcessTemperature.Current °C, Dec.1
Operation Timer
V_OperationTime.Power-up s
Ambient Pressure
V_AmbientPressure.Current Pa
Supply Voltage
V_SupplyVoltage.Current V, Dec.1

Commissioning Menus

Identification Menu
V_VendorName
V_VendorText
V_ProductName
V_PartNumber
V_ProductID
V_ProductText
V_ApplicationSpecificTag
V_FunctionTag
V_LocationTag
V_SerialNumber
V_FirmwareRevision
V_HardwareRevision

Parameters Menu
Device Settings
V_SystemCommand, Button:=130
V_DeviceAccessLocks
MDC (Measurement Data Channel) Settings
V_MDCSelection.Source
MDC Descriptor
V_MDC_Descriptor
If V_DisplayControlValues.PV "Pressure" = 0:
Offset 1 (Pressure) Settings
V_ProcessValueOffset.Pressure * 1 Pa, Dec.0
If V_DisplayControlValues.PV "Pressure" = 1:
Offset 1 (Pressure) Settings
V_ProcessValueOffset.Pressure * 10 Pa, Dec.0
If V_DisplayControlValues.PV "Pressure" = 2:
Offset 1 (Pressure) Settings
V_ProcessValueOffset.Pressure * 100 Pa, Dec.0
If V_DisplayControlValues.PV "Pressure" = 3:
Offset 1 (Pressure) Settings
V_ProcessValueOffset.Pressure * 1000 Pa, Dec.0
If V_DisplayControlValues.PV "Pressure" = 4:
Offset 1 (Pressure) Settings
V_ProcessValueOffset.Pressure * 10000 Pa, Dec.0
If V_DisplayControlValues.PV "Process Temperature" = 15:
Offset 2 (Process Temperature) Settings
V_ProcessValueOffset.Process Temperature * 0.1 °C, Dec.1
SSC1 (Pressure) Settings
Configuration
V_SSC1_Config.Mode
V_SSC1_Config.Logic
If V_DisplayControlValues.PV "Pressure" = 0:
Setpoints
V_SSC1_Param.Setpoint 1 * 1 Pa, Dec.0
V_SSC1_Param.Setpoint 2 * 1 Pa, Dec.0
If V_DisplayControlValues.PV "Pressure" = 1:
Setpoints
V_SSC1_Param.Setpoint 1 * 10 Pa, Dec.0
V_SSC1_Param.Setpoint 2 * 10 Pa, Dec.0
If V_DisplayControlValues.PV "Pressure" = 2:
Setpoints
V_SSC1_Param.Setpoint 1 * 100 Pa, Dec.0
V_SSC1_Param.Setpoint 2 * 100 Pa, Dec.0
If V_DisplayControlValues.PV "Pressure" = 3:
Setpoints
V_SSC1_Param.Setpoint 1 * 1000 Pa, Dec.0
V_SSC1_Param.Setpoint 2 * 1000 Pa, Dec.0
If V_DisplayControlValues.PV "Pressure" = 4:
Setpoints
V_SSC1_Param.Setpoint 1 * 10000 Pa, Dec.0
V_SSC1_Param.Setpoint 2 * 10000 Pa, Dec.0
SSC2 (Process Temperature) Settings
Configuration
V_SSC2_Config.Mode
If V_DisplayControlValues.PV "Process Temperature" = 15:
Setpoints
V_SSC2_Param.Setpoint 1 * 0.1 °C, Dec.1
V_SSC2_Param.Setpoint 2 * 0.1 °C, Dec.1
Analog Output
V_AnalogOutputSettings.State Signal * 1 mA, Dec.1
Data for external Applications
V_DisplayControlValues.Selected PV
V_DisplayControlValues.PV "Pressure"
V_DisplayControlValues.PV "Process Temperature"

Diagnosis Menu
V_DeviceStatus
Detailed Device Status
V_DetailedDeviceStatus
Device Temperature
V_DeviceTemperature.Current °C, Dec.1
CPU Temperature
V_CpuTemperature.Current °C, Dec.1
Process Temperature
V_ProcessTemperature.Current °C, Dec.1
Operation Timer
V_OperationTime.Power-up s
Ambient Pressure
V_AmbientPressure.Current Pa
Supply Voltage
V_SupplyVoltage.Current V, Dec.1

Note: This page shows the content of an IODD file transformed into HTML format. In the case of disparity between this and the XML view, the content of the XML file takes precedence.
Created by IODD Viewer V1.2.