Version: V1.1Release Date: 2022-04-29


OT500.DL-I
Vendor ID 350 (0x015e) Vendor Logo
Vendor Name Baumer Electric AG
Vendor Text Passion for Sensors
Vendor URL https://www.baumer.com
Device ID 757 (0x0002f5)
DeviceFamily OT500
Features
Block Parameter yes
Data Storage yes
Profile Characteristic 0x0010 (Device Profile: Measuring and Switching Sensor, 1 channel), 0x4000 (Common Application Profile: Identification and Diagnosis), 0x800c (Function Class: Sensor control), 0x8011 (Function Class: Teach two point extension), 0x8012 (Function Class: Teach dynamic extension), 0x8013 (Function Class: ?Unknown?)
Supported Access Locks Parameter: no, Data Storage: no, Local Parameterization: yes, Local User Interface: no
Communication
IO-Link Revision V1.1
Transmission Rate230400 bit/s (COM3)
Minimum Cycle Time 2 ms
SIO Mode Supported yes
M-Sequence CapabilityPREOPERATE = TYPE_1_V with 8 octets on-request data
OPERATE = TYPE_2_V with 8 octets on-request data
ISDU supported
Device Variant OT500.DL-GLIAJ.72F
Description Distance sensor, 1 switching output, 1 analog output 4-20mA
Product ID 11240053
Device Icon Device Icon
Device Symbol Device Symbol
Connection TypeNon-standard connector
Connection Description M12-5 connector with 1 switching and 1 analog output
- pin 1 brown; L+; Power Supply
- pin 2 white; Other; Analog
- pin 3 (light) blue; L-; Power Supply
- pin 4 black; C/Q; SIO/IO-Link
- pin 5 grey (slate); Other; Control

ProcessData id=P_ProcessDataDistance (condition V_MDCSelection.Source = 0)

ProcessDataIn "Process Data In (Distance)" id=PI_ProcessDataInDistance

bit length: 32
data type: 32-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 16-bit Integer -32760 = Out of Range (-), 32760 = Out of Range (+), 32764 = No Data, 100..2700 Measurement Value
3 0 Boolean SSC1/Distance
4 1 Boolean SSC2/Distance
5 2 Boolean Quality Bit
6 3 Boolean Alarm Output
7 5 Boolean SSC4/Counter
Octet 0
bit offset 31 30 29 28 27 26 25 24
subindex 1
element bit 15 14 13 12 11 10 9 8
Octet 1
bit offset 23 22 21 20 19 18 17 16
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 2
bit offset 15 14 13 12 11 10 9 8
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
Octet 3
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / 7 / / / / / / 6 5 4 3

ProcessDataOut "Process Data Out" id=PO_ProcessDataOutDistance

bit length: 2
data type: 2-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Boolean Disable Laser
2 1 Boolean Find Me
Octet 0
bit offset 7 6 5 4 3 2 1 0
subindex             2 1

ProcessData id=P_ProcessDataQuality (condition V_MDCSelection.Source = 1)

ProcessDataIn "Process Data In (Quality)" id=PI_ProcessDataInQuality

bit length: 32
data type: 32-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 16-bit Integer 0..99 = No measurement possible, 100..3000 Quality Value
3 0 Boolean SSC1/Distance
4 1 Boolean SSC2/Distance
5 2 Boolean Quality Bit
6 3 Boolean Alarm Output
7 5 Boolean SSC4/Counter
Octet 0
bit offset 31 30 29 28 27 26 25 24
subindex 1
element bit 15 14 13 12 11 10 9 8
Octet 1
bit offset 23 22 21 20 19 18 17 16
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 2
bit offset 15 14 13 12 11 10 9 8
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
Octet 3
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / 7 / / / / / / 6 5 4 3

ProcessDataOut "Process Data Out" id=PO_ProcessDataOutQuality

bit length: 2
data type: 2-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Boolean Disable Laser
2 1 Boolean Find Me
Octet 0
bit offset 7 6 5 4 3 2 1 0
subindex             2 1

ProcessData id=P_ProcessDataCounterSSC1 (condition V_MDCSelection.Source = 2)

ProcessDataIn "Process Data In (SSC1 Counter)" id=PI_ProcessDataInCounterSSC1

bit length: 32
data type: 32-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 16-bit UInteger 0..60000 Counter Value SSC1
3 0 Boolean SSC1/Distance
4 1 Boolean SSC2/Distance
5 2 Boolean Quality Bit
6 3 Boolean Alarm Output
7 5 Boolean SSC4/Counter
Octet 0
bit offset 31 30 29 28 27 26 25 24
subindex 1
element bit 15 14 13 12 11 10 9 8
Octet 1
bit offset 23 22 21 20 19 18 17 16
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 2
bit offset 15 14 13 12 11 10 9 8
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
Octet 3
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / 7 / / / / / / 6 5 4 3

ProcessDataOut "Process Data Out" id=PO_ProcessDataOutCounterSSC1

bit length: 2
data type: 2-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Boolean Disable Laser
2 1 Boolean Find Me
Octet 0
bit offset 7 6 5 4 3 2 1 0
subindex             2 1

ProcessData id=P_ProcessDataCounterSSC2 (condition V_MDCSelection.Source = 3)

ProcessDataIn "Process Data In (SSC2 Counter)" id=PI_ProcessDataInCounterSSC2

bit length: 32
data type: 32-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 16-bit UInteger 0..60000 Counter Value SSC2
3 0 Boolean SSC1/Distance
4 1 Boolean SSC2/Distance
5 2 Boolean Quality Bit
6 3 Boolean Alarm Output
7 5 Boolean SSC4/Counter
Octet 0
bit offset 31 30 29 28 27 26 25 24
subindex 1
element bit 15 14 13 12 11 10 9 8
Octet 1
bit offset 23 22 21 20 19 18 17 16
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 2
bit offset 15 14 13 12 11 10 9 8
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
Octet 3
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / 7 / / / / / / 6 5 4 3

ProcessDataOut "Process Data Out" id=PO_ProcessDataOutCounterSSC2

bit length: 2
data type: 2-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Boolean Disable Laser
2 1 Boolean Find Me
Octet 0
bit offset 7 6 5 4 3 2 1 0
subindex             2 1

ProcessData id=P_ProcessDataCounterSSC4 (condition V_MDCSelection.Source = 4)

ProcessDataIn "Process Data In (SSC4 Counter)" id=PI_ProcessDataInCounterSSC4

bit length: 32
data type: 32-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 16-bit UInteger 0..60000 Counter Value SSC4
3 0 Boolean SSC1/Distance
4 1 Boolean SSC2/Distance
5 2 Boolean Quality Bit
6 3 Boolean Alarm Output
7 5 Boolean SSC4/Counter
Octet 0
bit offset 31 30 29 28 27 26 25 24
subindex 1
element bit 15 14 13 12 11 10 9 8
Octet 1
bit offset 23 22 21 20 19 18 17 16
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 2
bit offset 15 14 13 12 11 10 9 8
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
Octet 3
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / 7 / / / / / / 6 5 4 3

ProcessDataOut "Process Data Out" id=PO_ProcessDataOutCounterSSC4

bit length: 2
data type: 2-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Boolean Disable Laser
2 1 Boolean Find Me
Octet 0
bit offset 7 6 5 4 3 2 1 0
subindex             2 1

Standard Variable "Direct Parameters - Page 1" index=0 id=V_DirectParameters_1

description: Comprises the required parameters defining the communication characteristics and identifiers for device validation.
data type: 128-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 120 8-bit UInteger ro Reserved
2 112 8-bit UInteger ro Master Cycle Time Communication: Current communication cycle duration used by the master. This value defines the process data cycle.
3 104 8-bit UInteger ro Min Cycle Time Communication: Minimum communication cycle duration supported by the device. This value defines the lowest possible process data cycle.
4 96 8-bit UInteger ro M-Sequence Capability Communication: Information on the structure and the supported features of the communication messages.
5 88 8-bit UInteger 17 ro IO-Link Revision ID Communication: Identifier for the currently used communication protocol revision.
6 80 8-bit UInteger ro Process Data Input Length Communication: Information on width and features of the process input data (Process Data from Device to Master).
7 72 8-bit UInteger ro Process Data Output Length Communication: Information on width of the process output data (Process Data from Master to Device).
8 64 8-bit UInteger ro Vendor ID 1 Identification: Highest octet of the Vendor ID. Combined with the parameter Vendor ID 2, this parameter defines the 16-bit value of the unique Vendor ID as assigned by the IO-Link Community.
9 56 8-bit UInteger ro Vendor ID 2 Identification: Lowest octet of the Vendor ID. Combined with the parameter Vendor ID 1, this parameter defines the 16-bit value of the unique Vendor ID as assigned by the IO-Link Community.
10 48 8-bit UInteger ro Device ID 1 Identification: Highest octet of the Device ID. Combined with the parameters Device ID 2 and 3, this parameter defines the 24-bit value of the vendor-specific Device ID.
11 40 8-bit UInteger ro Device ID 2 Identification: Middle octet of the Device ID. Combined with the parameters Device ID 1 and 3, this parameter defines the 24-bit value of the vendor-specific Device ID.
12 32 8-bit UInteger ro Device ID 3 Identification: Lowest octet of the Device ID. Combined with the parameters Device ID 1 and 2, this parameter defines the 24-bit value of the vendor-specific Device ID.
13 24 8-bit UInteger ro Reserved
14 16 8-bit UInteger ro Reserved
15 8 8-bit UInteger ro Reserved
16 0 8-bit UInteger wo X System Command Application: Command interface for devices without ISDU support. Validity and execution of commands are not confirmed.

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 1 2 3 4 5 6 7 8
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 9 10 11 12 13 14 15 16
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

Standard Variable "System Command" index=2 id=V_SystemCommand

description: Command interface for applications. A positive acknowledge indicates the complete and correct finalization of the requested function.
data type: 8-bit UInteger
allowed values: 64 = Teach Apply, 65 = Teach SP1, 66 = Teach SP2, 67 = Teach SP1 TP1, 68 = Teach SP1 TP2, 69 = Teach SP2 TP1, 70 = Teach SP2 TP2, 71 = Teach SP1 Start, 72 = Teach SP1 Stop, 73 = Teach SP2 Start, 74 = Teach SP2 Stop, 79 = Teach Cancel, 128 = Device Reset, 129 = Application Reset, 130 = Restore Factory Settings, 131 = Back-to-box
access rights: wo
modifies other variables

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Standard Variable "Device Access Locks" index=12 id=V_DeviceAccessLocks

description: The access to the device parameters can be restricted by setting appropriate flags within this parameter.
data type: 16-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Boolean false = Unlocked, true = Locked Parameter Write Access This lock prevents the write access to all read/write parameters of the device except for the parameter 'Device Access Locks'.
2 1 Boolean false = Unlocked, true = Locked Data Storage This lock prevents the write access to the device parameters via the data storage mechanism.
3 2 Boolean false = Unlocked, true = Locked false Local Parameterization This lock prevents the device settings from being changed via local operating elements on the device.
4 3 Boolean false = Unlocked, true = Locked Local User Interface This lock prevents the access to the device settings and display via a local user interface. The user interface is disabled.
Octet 0
bit offset 15 14 13 12 11 10 9 8
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
Octet 1
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / 4 3 2 1

Standard Variable "Vendor Name" index=16 id=V_VendorName

description: The vendor name that is assigned to a Vendor ID.
data type: 32-octet String UTF-8
default value: "Baumer Electric AG"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Vendor Text" index=17 id=V_VendorText

description: Additional information about the vendor.
data type: 32-octet String UTF-8
default value: "https://www.baumer.com"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Product Name" index=18 id=V_ProductName

description: Complete product name.
data type: 51-octet String UTF-8
default value: "OT500.DL-GLIAJ.72F"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 407 - 400 399 - 392 391 - 384 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344

octet 8 9 10 11 12 13 14 15
bit offset 343 - 336 335 - 328 327 - 320 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280

octet 16 17 18 19 20 21 22 23
bit offset 279 - 272 271 - 264 263 - 256 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216

octet 24 25 26 27 28 29 30 31
bit offset 215 - 208 207 - 200 199 - 192 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152

octet 32 33 34 35 36 37 38 39
bit offset 151 - 144 143 - 136 135 - 128 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88

octet 40 41 42 43 44 45 46 47
bit offset 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24

octet 48 49 50  
bit offset 23 - 16 15 - 8 7 - 0  

Standard Variable "Product ID" index=19 id=V_ProductID

description: Vendor-specific product or type identification (e.g., item number or model number).
data type: 8-octet String UTF-8
default value: "11240053"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Product Text" index=20 id=V_ProductText

description: Additional product information for the device.
data type: 64-octet String UTF-8
default value: "Distance sensor"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Serial Number" index=21 id=V_SerialNumber

description: Unique, vendor-specific identifier of the individual device.
data type: 16-octet String UTF-8
default value: "M11210U-12345678"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Hardware Revision" index=22 id=V_HardwareRevision

description: Unique, vendor-specific identifier of the hardware revision of the individual device.
data type: 8-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Firmware Revision" index=23 id=V_FirmwareRevision

description: Unique, vendor-specific identifier of the firmware revision of the individual device.
data type: 8-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Application-specific Tag" index=24 id=V_ApplicationSpecificTag

description: Possibility to mark a device with user- or application-specific information.
data type: 32-octet String UTF-8
default value: "***"
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Device Status" index=36 id=V_DeviceStatus

description: Indicator for the current device condition and diagnosis state.
data type: 8-bit UInteger
allowed values: 0 = Device is OK, 1 = Maintenance required, 2 = Out of specification, 3 = Functional check, 4 = Failure
access rights: ro
dynamic

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Standard Variable "Detailed Device Status" index=37 id=V_DetailedDeviceStatus

description: List of all currently pending events in the device.
data type: Array[5] of 3-octet OctetString (subindex access not supported)
access rights: ro
dynamic

octet 0 1 2 3 4 5 6 7
bit offset 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56
subindex 1 1 1 2 2 2 3 3

octet 8 9 10 11 12 13 14  
bit offset 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 3 4 4 4 5 5 5  

Standard Variable "PD Input" index=40 id=V_ProcessDataInput

description: Last valid process input data of the device.
data type: see ProcessDataIn!
access rights: ro
dynamic

Standard Variable "PD Output" index=41 id=V_ProcessDataOutput

description: Last valid process output data written to the device.
data type: see ProcessDataOut!
access rights: ro
dynamic

Variable "Function Tag" index=25 id=V_CP_FunctionTag

description: User specified function tag
data type: 32-octet String UTF-8
default value: "***"
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Location Tag" index=26 id=V_CP_LocationTag

description: User specified location tag
data type: 32-octet String UTF-8
default value: "***"
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Teach Select" index=58 id=V_SSP_TeachSelect

description: Selects the switching signal channel for which a teach procedure will be applied.
data type: 8-bit UInteger
allowed values: 1 = SSC.1, 2 = SSC.2
default value: 1
access rights: rw
excluded from data storage

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Teach Result" index=59 id=V_SSP_TeachResult

description: Shows the complete result information including current state and result flags of the teach procedure.
data type: 8-bit Record (subindex access not supported)
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 4-bit UInteger 0 = Idle, 1 = SP1 success, 2 = SP2 success, 3 = SP1, SP2 success, 4 = Wait for command, 5 = Busy, 7 = Error 0 State Indicates the current state of the teach procedure.
2 4 Boolean false = Initial or not ok, true = Ok 0 Flag SP1 TP1 Indicates the current teach result for the teach point.
3 5 Boolean false = Initial or not ok, true = Ok 0 Flag SP1 TP2 Indicates the current teach result for the teach point.
4 6 Boolean false = Initial or not ok, true = Ok 0 Flag SP2 TP1 Indicates the current teach result for the teach point.
5 7 Boolean false = Initial or not ok, true = Ok 0 Flag SP2 TP2 Indicates the current teach result for the teach point.
Octet 0
bit offset 7 6 5 4 3 2 1 0
subindex 5 4 3 2 1
element bit         3 2 1 0

Variable "SSC.1 Param" index=60 id=V_SSP_SSC01_Param

description: Defines the setpoint values for switching signal channel 1.
data type: 64-bit Record
access rights: rw
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 32 32-bit Integer 100..2700 2625 SP1 Defines the setpoint 1 value for the switching signal channel.
2 0 32-bit Integer 100..2700 2625 SP2 Defines the setpoint 2 value for the switching signal channel.

octet 0 1 2 3 4 5 6 7
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "SSC.1 Config" index=61 id=V_SSP_SSC01_Config

description: Defines the configuration parameter for switching signal channel 1.
data type: 48-bit Record
access rights: rw
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 40 8-bit UInteger 0 = High active, 1 = Low active 0 Logic Defines the logical representation of the switching signal SSC in the process data.
2 32 8-bit UInteger 0 = Deactivated, 1 = Single point, 2 = Window, 3 = Two point 1 Mode Defines the evaluation mode for the switching signal SSC.
3 0 32-bit Integer 0 ro Hyst Defines the hysteresis at the switchpoint. A higher hysteresis may help to increase stability in critical applications.

octet 0 1 2 3 4 5  
bit offset 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 2 3 3 3 3  
element bit 7 - 0 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "SSC.2 Param" index=62 id=V_SSP_SSC02_Param

description: Defines the setpoint values for switching signal channel 2.
data type: 64-bit Record
access rights: rw
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 32 32-bit Integer 100..2700 2625 SP1 Defines the setpoint 1 value for the switching signal channel.
2 0 32-bit Integer 100..2700 2625 SP2 Defines the setpoint 2 value for the switching signal channel.

octet 0 1 2 3 4 5 6 7
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "SSC.2 Config" index=63 id=V_SSP_SSC02_Config

description: Defines the configuration parameter for switching signal channel 2.
data type: 48-bit Record
access rights: rw
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 40 8-bit UInteger 0 = High active, 1 = Low active 0 Logic Defines the logical representation of the switching signal SSC in the process data.
2 32 8-bit UInteger 0 = Deactivated, 1 = Single point, 2 = Window, 3 = Two point 1 Mode Defines the evaluation mode for the switching signal SSC.
3 0 32-bit Integer 0 ro Hyst Defines the hysteresis at the switchpoint. A higher hysteresis may help to increase stability in critical applications.

octet 0 1 2 3 4 5  
bit offset 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 2 3 3 3 3  
element bit 7 - 0 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Quality" index=64 id=V_QualityValue

description: Quality value settings
data type: 16-bit Record (subindex access not supported)
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 16-bit Integer 0..99 = No measurement possible, 100..3000 3000 Value Quality value indicates the quality of the reflected signal

octet 0 1  
bit offset 15 - 8 7 - 0  
subindex 1 1  
element bit 15 - 8 7 - 0  

Variable "Quality Bit" index=65 id=V_QualityBitThreshold

description: Quality bit settings
data type: 16-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 16-bit Integer 0..99 = No measurement possible, 100..3000 150 Threshold Selects the Quality Threshold, if the quality value is below the threshold the LEDs start to blink and the quality bit in the process data is set to 1

octet 0 1  
bit offset 15 - 8 7 - 0  
subindex 1 1  
element bit 15 - 8 7 - 0  

Variable "Hysteresis" index=69 id=V_SSC_HysteresisSettings

description: Switching signal channel hysteresis settings
data type: 16-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
5 8 8-bit UInteger 1 = Left Aligned, 2 = Center Aligned, 3 = Right Aligned 3 SSC1 Alignment Set hysteresis alignment
15 0 8-bit UInteger 1 = Left Aligned, 2 = Center Aligned, 3 = Right Aligned 3 SSC2 Alignment Set hysteresis alignment

octet 0 1  
bit offset 15 - 8 7 - 0  
subindex 5 15  
element bit 7 - 0 7 - 0  

Variable "Unit Selection" index=74 id=V_UnitSelection

description: Unit selection used to output measurement values
data type: 16-bit Record (subindex access not supported)
access rights: rw
modifies other variables

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 16-bit UInteger 1000 = Kelvin, 1001 = Celsius, 1002 = Fahrenheit 1001 Temperature Select temperature unit (rw parameter in menu Parameter/ Temperature Settings, ro in menu Diagnosis/ Device Temperature)

octet 0 1  
bit offset 15 - 8 7 - 0  
subindex 1 1  
element bit 15 - 8 7 - 0  

Variable "Operation Modes" index=77 id=V_OperationModes

description: Various Operation Modes
data type: 8-bit Record
access rights: rw
modifies other variables

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 8-bit UInteger 0 = Fast, 1 = Standard, 6 = Long Range 1 Measurement Mode Mode of measurement

octet 0  
bit offset 7 - 0  
subindex 1  
element bit 7 - 0  

Variable "DI/DO Settings" index=78 id=V_DIDOSettings

data type: 24-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 8-bit UInteger 1 = Push-Pull, 2 = PNP, 3 = NPN 1 OUT1 Circuit Select the output circuit. Changes get active after a sensor reset.
2 0 16-bit UInteger 100 = SSC1, 400 = SSC4, 1701 = Alarm, 1702 = Quality 100 OUT1 Function Select the output function

octet 0 1 2  
bit offset 23 - 16 15 - 8 7 - 0  
subindex 1 2 2  
element bit 7 - 0 15 - 8 7 - 0  

Variable "LED Settings" index=79 id=V_LedSettings

description: LED operation settings
data type: 24-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
2 16 8-bit UInteger 0 = Off, 1 = On 1 Green Mode Switches the LED off, no change of other function
12 8 8-bit UInteger 0 = Off, 1 = On, 2 = Inverted 1 Yellow Mode Switches the LED off, no change of other function, or inverts the relationship between LED and pin, Inverted: Pin high, LED off, On: Pin high, LED on
22 0 8-bit UInteger 0 = Off, 1 = On 1 Blue Mode Switches the LED off, no change of other function

octet 0 1 2  
bit offset 23 - 16 15 - 8 7 - 0  
subindex 2 12 22  
element bit 7 - 0 7 - 0 7 - 0  

Variable "Teach Lock Settings" index=80 id=V_TeachLockSettings

description: Teach lock settings
data type: 8-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 8-bit UInteger 5 qTeach Time Out Time until qTeach is locked. If 0 qTeach never locks. If 0xFF qTeach always off

octet 0  
bit offset 7 - 0  
subindex 1  
element bit 7 - 0  

Variable "Profiles" index=82 id=V_ConfigurationProfiles

description: Profile settings
data type: 8-bit Record (subindex access not supported)
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 8-bit UInteger 0 = Custom, 1 = Standard, 2 = Fast, 3 = Long Range 1 Active Profile Currently active profile

octet 0  
bit offset 7 - 0  
subindex 1  
element bit 7 - 0  

Variable "MDC Selection" index=83 id=V_MDCSelection

data type: 8-bit Record (subindex access not supported)
access rights: rw
modifies other variables

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 8-bit UInteger 0 = Distance, 1 = Quality, 2 = SSC1 Switch Counter, 3 = SSC2 Switch Counter, 4 = SSC4 Switch Counter 0 Source Select the process value that is shown on the MDC channel

octet 0  
bit offset 7 - 0  
subindex 1  
element bit 7 - 0  

Variable "SSC Source Settings" index=85 id=V_SSC_SourceSettings

data type: 16-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
31 8 8-bit UInteger 0 = Disabled, 1 = SSC1 Switch Counter, 2 = SSC2 Switch Counter 0 SSC4 Source Selection Select the process value that is shown on the MDC channel
32 0 8-bit UInteger 0 = Disabled, 1 = Enabled 0 SSC4 Auto Reset SSC4 Auto Reset

octet 0 1  
bit offset 15 - 8 7 - 0  
subindex 31 32  
element bit 7 - 0 7 - 0  

Variable "Measurement Values" index=88 id=V_MeasurementValues

data type: 32-bit Record
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 16-bit Integer -32760 = Out of Range (-), 32760 = Out of Range (+), 32764 = No Data, 100..2700 2625 Distance Measured Distance
11 0 16-bit UInteger 0..60000 0 Counter Value Current Counter Value

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 11 11  
element bit 15 - 8 7 - 0 15 - 8 7 - 0  

Variable "Switchpoint Settings" index=99 id=V_SwitchpointSettings

description: Switchpoint Settings
data type: 64-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 32 32-bit Integer -50..50 5 Teachpoint Offset.SSC1 Teachpoint offset for SSC1
11 0 32-bit Integer -50..50 5 Teachpoint Offset.SSC2 Teachpoint offset for SSC2

octet 0 1 2 3 4 5 6 7
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 1 1 1 1 11 11 11 11
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Teach Mode Settings" index=100 id=V_TeachModeSettings

description: Settings configuring the teach modes
data type: 8-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 8-bit UInteger 0 = XPert static, 1 = XPress static 0 Local Teach Mode Selects the teach mode if more than one is available. Teach modes: 0: xPert: normal method, 1: xPress: simplified method

octet 0  
bit offset 7 - 0  
subindex 1  
element bit 7 - 0  

Variable "Analog Output Settings" index=116 id=V_AnalogOutputSettings

description: Settings for analog output
data type: 8-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
4 0 8-bit UInteger 1 = Min, 2 = Max, 4 = Freeze 2 Analog Alarm Mode Analog output setting when alarm is active

octet 0  
bit offset 7 - 0  
subindex 4  
element bit 7 - 0  

Variable "Release Delay" index=120 id=V_SSC_ReleaseDelay

description: The binary release delay filter delays the resetting of the given switching signal channel by the time indicated. The delay affects the IO-Link process data and the related physical output as far as available for the sensor type.
data type: 96-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
2 64 32-bit UInteger 0..60000 0 SSC1 Time Sets / indicates the response delay time in milliseconds for SSC1.
12 32 32-bit UInteger 0..60000 0 SSC2 Time Sets / indicates the response delay time in milliseconds for SSC2.
32 0 32-bit UInteger 0..60000 0 SSC4 Time Sets / indicates the response delay time in milliseconds for SSC4.

octet 0 1 2 3 4 5 6 7
bit offset 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32
subindex 2 2 2 2 12 12 12 12
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 32 32 32 32  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Response Delay" index=121 id=V_SSC_ResponseDelay

description: The binary response delay filter delays the setting of the given switching signal channel by the time indicated. The delay affects the IO-Link process data and the related physical output as far as available for the sensor type.
data type: 96-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
2 64 32-bit UInteger 0..60000 0 SSC1 Time Sets / indicates the response delay time in milliseconds for SSC1.
12 32 32-bit UInteger 0..60000 0 SSC2 Time Sets / indicates the response delay time in milliseconds for SSC2.
32 0 32-bit UInteger 0..60000 0 SSC4 Time Sets / indicates the response delay time in milliseconds for SSC4.

octet 0 1 2 3 4 5 6 7
bit offset 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32
subindex 2 2 2 2 12 12 12 12
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 32 32 32 32  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Minimal Pulse Duration" index=122 id=V_SSC_MinPulseDuration

description: The binary response delay filter delays the setting of the given switching signal channel by the time indicated. The delay affects the IO-Link process data and the related physical output as far as available for the sensor type.
data type: 120-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
2 88 32-bit UInteger 0..60000 0 SSC1 Time Sets / indicates the minimal pulse length in milliseconds for the respective switching signal channel (SSC).
3 80 8-bit UInteger 1 = Both Pulses, 2 = Positive Pulse, 3 = Negative Pulse 1 SSC1 Mode 1: Both Pulses: positive and negative pulses are prolonged; 2: Positive Pulse: only positive pulses are prolonged; 3: Negative Pulse: only negative pulses are prolonged
12 48 32-bit UInteger 0..60000 0 SSC2 Time Sets / indicates the minimal pulse length in milliseconds for the respective switching signal channel (SSC).
13 40 8-bit UInteger 1 = Both Pulses, 2 = Positive Pulse, 3 = Negative Pulse 1 SSC2 Mode 1: Both Pulses: positive and negative pulses are prolonged; 2: Positive Pulse: only positive pulses are prolonged; 3: Negative Pulse: only negative pulses are prolonged
32 8 32-bit UInteger 0..60000 0 SSC4 Time Sets / indicates the minimal pulse length in milliseconds for the respective switching signal channel (SSC).
33 0 8-bit UInteger 1 = Both Pulses, 2 = Positive Pulse, 3 = Negative Pulse 1 SSC4 Mode 1: Both Pulses: positive and negative pulses are prolonged; 2: Positive Pulse: only positive pulses are prolonged; 3: Negative Pulse: only negative pulses are prolonged

octet 0 1 2 3 4 5 6 7
bit offset 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56
subindex 2 2 2 2 3 12 12 12
element bit 31 - 24 23 - 16 15 - 8 7 - 0 7 - 0 31 - 24 23 - 16 15 - 8

octet 8 9 10 11 12 13 14  
bit offset 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 12 13 32 32 32 32 33  
element bit 7 - 0 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0 7 - 0  

Variable "Process Value Disruption Filter" index=164 id=V_PV_DisruptionFilter

description: Disruption filter inhibits short timed measurement value changes over a given interval
data type: 64-bit Record (subindex access not supported)
access rights: rw
modifies other variables

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
2 32 32-bit UInteger 0..65535 4 Maximum perturbation time Duration (in units of time) until a signal (as defined in the parameter .Distance) becomes visible at the output.
3 0 32-bit UInteger 0..65535 100 Distance Distance deviations from the current measured value which are ignored, if shorter than the period set by the parameter '.Maximum perturbation time'.

octet 0 1 2 3 4 5 6 7
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 2 2 2 2 3 3 3 3
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Exponential Filter" index=165 id=V_PV_ExponentialFilter

description: Exponential smoothing filter
data type: 32-bit Record (subindex access not supported)
access rights: rw
modifies other variables

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
2 0 32-bit UInteger 0..65535 5 Smoothing Factor Smoothing Factor

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 2 2 2 2  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Analog Output Scaler" index=202 id=V_Output_2PointScaler

description: Allows to scale an input value to the output
data type: 128-bit Record
access rights: rw
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
2 96 32-bit Integer 100..2700 150 Corner 1 Input Corner 1 input process value
3 64 32-bit Integer 40..200 40 Corner 1 Output Corner 1 output analog value
4 32 32-bit Integer 100..2700 2500 Corner 2 Input Corner 2 input process value
5 0 32-bit Integer 40..200 200 Corner 2 Output Corner 2 output analog value

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 2 2 2 2 3 3 3 3
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 4 4 4 4 5 5 5 5
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Device Temperature" index=208 id=V_DeviceTemperature

data type: 160-bit Record (subindex access not supported)
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 128 Float32 -460..420 0.0 Current Current value
2 96 Float32 -460..420 0.0 Resetable Min Minimal value (resetable)
3 64 Float32 -460..420 0.0 Resetable Max Maximal value (resetable)
4 32 Float32 -460..420 0.0 Lifetime Min Minimal value (Lifetime)
5 0 Float32 -460..420 0.0 Lifetime Max Maximal value (Lifetime)

octet 0 1 2 3 4 5 6 7
bit offset 159 - 152 151 - 144 143 - 136 135 - 128 127 - 120 119 - 112 111 - 104 103 - 96
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32
subindex 3 3 3 3 4 4 4 4
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 16 17 18 19  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 5 5 5 5  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Power Supply Voltage" index=210 id=V_PowerSupplyVoltage

data type: 160-bit Record (subindex access not supported)
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 128 Float32 0..30 0.0 Current Current value
2 96 Float32 0..30 0.0 Resetable Min Minimal value (resetable)
3 64 Float32 0..30 0.0 Resetable Max Maximal value (resetable)
4 32 Float32 0..30 0.0 Lifetime Min Minimal value (Lifetime)
5 0 Float32 0..30 0.0 Lifetime Max Maximal value (Lifetime)

octet 0 1 2 3 4 5 6 7
bit offset 159 - 152 151 - 144 143 - 136 135 - 128 127 - 120 119 - 112 111 - 104 103 - 96
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32
subindex 3 3 3 3 4 4 4 4
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 16 17 18 19  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 5 5 5 5  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Operation Time" index=211 id=V_OperationTime

data type: 96-bit Record (subindex access not supported)
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 64 32-bit UInteger 0 Powerup Operation time on power-up
2 32 32-bit UInteger 0 Resetable Operation time (Resetable by user command)
3 0 32-bit UInteger 0 Lifetime Lifetime operation time

octet 0 1 2 3 4 5 6 7
bit offset 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 3 3 3 3  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Bootcycles" index=224 id=V_Bootcycles

data type: 32-bit Record (subindex access not supported)
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
2 0 32-bit UInteger 0 Lifetime Total number of bootcycles over the complete lifetime

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 2 2 2 2  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "SSC Switch Counts" index=225 id=V_SSCSwitchCounts

data type: 96-bit Record (subindex access not supported)
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
2 64 32-bit UInteger 0 SSC1 Resetable Total number of switch counts on SSC1 (resetable by user command-> SSC1 Switch Counts Reset)
12 32 32-bit UInteger 0 SSC2 Resetable Total number of switch counts on SSC2 (resetable by user command-> SSC2 Switch Counts Reset)
32 0 32-bit UInteger 0 SSC4 Resetable Total number of switch counts on SSC4 (resetable by user command-> SSC4 Switch Counts Reset)

octet 0 1 2 3 4 5 6 7
bit offset 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32
subindex 2 2 2 2 12 12 12 12
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 32 32 32 32  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Distance Resetable Histogram" index=257 id=V_ProcessValue1ResetableHistogram

data type: 608-bit Record (subindex access not supported)
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 600 8-bit UInteger 0 = Linear, 1 = Custom 0 Mode Mode
2 584 16-bit UInteger 1000 = Kelvin, 1001 = Celsius, 1002 = Fahrenheit, 1013 = Millimeter, 1240 = Volt 1001 Unit Unit
3 552 Float32 100 Range Start Start of range
4 520 Float32 2700 Range End End of range
5 512 8-bit UInteger 16 Nbr of Bins Number of acquired bins
11 480 32-bit UInteger Bin 1 Bin 1
12 448 32-bit UInteger Bin 2 Bin 2
13 416 32-bit UInteger Bin 3 Bin 3
14 384 32-bit UInteger Bin 4 Bin 4
15 352 32-bit UInteger Bin 5 Bin 5
16 320 32-bit UInteger Bin 6 Bin 6
17 288 32-bit UInteger Bin 7 Bin 7
18 256 32-bit UInteger Bin 8 Bin 8
19 224 32-bit UInteger Bin 9 Bin 9
20 192 32-bit UInteger Bin 10 Bin 10
21 160 32-bit UInteger Bin 11 Bin 11
22 128 32-bit UInteger Bin 12 Bin 12
23 96 32-bit UInteger Bin 13 Bin 13
24 64 32-bit UInteger Bin 14 Bin 14
25 32 32-bit UInteger Bin 15 Bin 15
26 0 32-bit UInteger Bin 16 Bin 16

octet 0 1 2 3 4 5 6 7
bit offset 607 - 600 599 - 592 591 - 584 583 - 576 575 - 568 567 - 560 559 - 552 551 - 544
subindex 1 2 2 3 3 3 3 4
element bit 7 - 0 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24

octet 8 9 10 11 12 13 14 15
bit offset 543 - 536 535 - 528 527 - 520 519 - 512 511 - 504 503 - 496 495 - 488 487 - 480
subindex 4 4 4 5 11 11 11 11
element bit 23 - 16 15 - 8 7 - 0 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 16 17 18 19 20 21 22 23
bit offset 479 - 472 471 - 464 463 - 456 455 - 448 447 - 440 439 - 432 431 - 424 423 - 416
subindex 12 12 12 12 13 13 13 13
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 24 25 26 27 28 29 30 31
bit offset 415 - 408 407 - 400 399 - 392 391 - 384 383 - 376 375 - 368 367 - 360 359 - 352
subindex 14 14 14 14 15 15 15 15
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 32 33 34 35 36 37 38 39
bit offset 351 - 344 343 - 336 335 - 328 327 - 320 319 - 312 311 - 304 303 - 296 295 - 288
subindex 16 16 16 16 17 17 17 17
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 40 41 42 43 44 45 46 47
bit offset 287 - 280 279 - 272 271 - 264 263 - 256 255 - 248 247 - 240 239 - 232 231 - 224
subindex 18 18 18 18 19 19 19 19
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 48 49 50 51 52 53 54 55
bit offset 223 - 216 215 - 208 207 - 200 199 - 192 191 - 184 183 - 176 175 - 168 167 - 160
subindex 20 20 20 20 21 21 21 21
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 56 57 58 59 60 61 62 63
bit offset 159 - 152 151 - 144 143 - 136 135 - 128 127 - 120 119 - 112 111 - 104 103 - 96
subindex 22 22 22 22 23 23 23 23
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 64 65 66 67 68 69 70 71
bit offset 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32
subindex 24 24 24 24 25 25 25 25
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 72 73 74 75  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 26 26 26 26  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Power Supply Voltage Lifetime Histogram" index=262 id=V_PowerSupplyVoltageLifetimeHistogram

data type: 608-bit Record (subindex access not supported)
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 600 8-bit UInteger 0 = Linear, 1 = Custom 0 Mode Mode
2 584 16-bit UInteger 1000 = Kelvin, 1001 = Celsius, 1002 = Fahrenheit, 1013 = Millimeter, 1240 = Volt 1240 Unit Unit
3 552 Float32 0 Range Start Start of range
4 520 Float32 32 Range End End of range
5 512 8-bit UInteger 16 Nbr of Bins Number of acquired bins
11 480 32-bit UInteger Bin 1 Bin 1
12 448 32-bit UInteger Bin 2 Bin 2
13 416 32-bit UInteger Bin 3 Bin 3
14 384 32-bit UInteger Bin 4 Bin 4
15 352 32-bit UInteger Bin 5 Bin 5
16 320 32-bit UInteger Bin 6 Bin 6
17 288 32-bit UInteger Bin 7 Bin 7
18 256 32-bit UInteger Bin 8 Bin 8
19 224 32-bit UInteger Bin 9 Bin 9
20 192 32-bit UInteger Bin 10 Bin 10
21 160 32-bit UInteger Bin 11 Bin 11
22 128 32-bit UInteger Bin 12 Bin 12
23 96 32-bit UInteger Bin 13 Bin 13
24 64 32-bit UInteger Bin 14 Bin 14
25 32 32-bit UInteger Bin 15 Bin 15
26 0 32-bit UInteger Bin 16 Bin 16

octet 0 1 2 3 4 5 6 7
bit offset 607 - 600 599 - 592 591 - 584 583 - 576 575 - 568 567 - 560 559 - 552 551 - 544
subindex 1 2 2 3 3 3 3 4
element bit 7 - 0 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24

octet 8 9 10 11 12 13 14 15
bit offset 543 - 536 535 - 528 527 - 520 519 - 512 511 - 504 503 - 496 495 - 488 487 - 480
subindex 4 4 4 5 11 11 11 11
element bit 23 - 16 15 - 8 7 - 0 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 16 17 18 19 20 21 22 23
bit offset 479 - 472 471 - 464 463 - 456 455 - 448 447 - 440 439 - 432 431 - 424 423 - 416
subindex 12 12 12 12 13 13 13 13
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 24 25 26 27 28 29 30 31
bit offset 415 - 408 407 - 400 399 - 392 391 - 384 383 - 376 375 - 368 367 - 360 359 - 352
subindex 14 14 14 14 15 15 15 15
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 32 33 34 35 36 37 38 39
bit offset 351 - 344 343 - 336 335 - 328 327 - 320 319 - 312 311 - 304 303 - 296 295 - 288
subindex 16 16 16 16 17 17 17 17
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 40 41 42 43 44 45 46 47
bit offset 287 - 280 279 - 272 271 - 264 263 - 256 255 - 248 247 - 240 239 - 232 231 - 224
subindex 18 18 18 18 19 19 19 19
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 48 49 50 51 52 53 54 55
bit offset 223 - 216 215 - 208 207 - 200 199 - 192 191 - 184 183 - 176 175 - 168 167 - 160
subindex 20 20 20 20 21 21 21 21
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 56 57 58 59 60 61 62 63
bit offset 159 - 152 151 - 144 143 - 136 135 - 128 127 - 120 119 - 112 111 - 104 103 - 96
subindex 22 22 22 22 23 23 23 23
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 64 65 66 67 68 69 70 71
bit offset 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32
subindex 24 24 24 24 25 25 25 25
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 72 73 74 75  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 26 26 26 26  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Device Temperature Lifetime Histogram" index=265 id=V_DeviceTemperatureLifetimeHistogram

data type: 608-bit Record (subindex access not supported)
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 600 8-bit UInteger 0 = Linear, 1 = Custom 0 Mode Mode
2 584 16-bit UInteger 1000 = Kelvin, 1001 = Celsius, 1002 = Fahrenheit, 1013 = Millimeter, 1240 = Volt 1013 Unit Unit
3 552 Float32 -40 Range Start Start of range
4 520 Float32 120 Range End End of range
5 512 8-bit UInteger 16 Nbr of Bins Number of acquired bins
11 480 32-bit UInteger Bin 1 Bin 1
12 448 32-bit UInteger Bin 2 Bin 2
13 416 32-bit UInteger Bin 3 Bin 3
14 384 32-bit UInteger Bin 4 Bin 4
15 352 32-bit UInteger Bin 5 Bin 5
16 320 32-bit UInteger Bin 6 Bin 6
17 288 32-bit UInteger Bin 7 Bin 7
18 256 32-bit UInteger Bin 8 Bin 8
19 224 32-bit UInteger Bin 9 Bin 9
20 192 32-bit UInteger Bin 10 Bin 10
21 160 32-bit UInteger Bin 11 Bin 11
22 128 32-bit UInteger Bin 12 Bin 12
23 96 32-bit UInteger Bin 13 Bin 13
24 64 32-bit UInteger Bin 14 Bin 14
25 32 32-bit UInteger Bin 15 Bin 15
26 0 32-bit UInteger Bin 16 Bin 16

octet 0 1 2 3 4 5 6 7
bit offset 607 - 600 599 - 592 591 - 584 583 - 576 575 - 568 567 - 560 559 - 552 551 - 544
subindex 1 2 2 3 3 3 3 4
element bit 7 - 0 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24

octet 8 9 10 11 12 13 14 15
bit offset 543 - 536 535 - 528 527 - 520 519 - 512 511 - 504 503 - 496 495 - 488 487 - 480
subindex 4 4 4 5 11 11 11 11
element bit 23 - 16 15 - 8 7 - 0 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 16 17 18 19 20 21 22 23
bit offset 479 - 472 471 - 464 463 - 456 455 - 448 447 - 440 439 - 432 431 - 424 423 - 416
subindex 12 12 12 12 13 13 13 13
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 24 25 26 27 28 29 30 31
bit offset 415 - 408 407 - 400 399 - 392 391 - 384 383 - 376 375 - 368 367 - 360 359 - 352
subindex 14 14 14 14 15 15 15 15
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 32 33 34 35 36 37 38 39
bit offset 351 - 344 343 - 336 335 - 328 327 - 320 319 - 312 311 - 304 303 - 296 295 - 288
subindex 16 16 16 16 17 17 17 17
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 40 41 42 43 44 45 46 47
bit offset 287 - 280 279 - 272 271 - 264 263 - 256 255 - 248 247 - 240 239 - 232 231 - 224
subindex 18 18 18 18 19 19 19 19
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 48 49 50 51 52 53 54 55
bit offset 223 - 216 215 - 208 207 - 200 199 - 192 191 - 184 183 - 176 175 - 168 167 - 160
subindex 20 20 20 20 21 21 21 21
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 56 57 58 59 60 61 62 63
bit offset 159 - 152 151 - 144 143 - 136 135 - 128 127 - 120 119 - 112 111 - 104 103 - 96
subindex 22 22 22 22 23 23 23 23
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 64 65 66 67 68 69 70 71
bit offset 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32
subindex 24 24 24 24 25 25 25 25
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 72 73 74 75  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 26 26 26 26  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Baumer Commands" index=1000 id=V_BaumerCommands

description: Baumer Commands
data type: 8-bit UInteger
allowed values: 1 = All Resetable Statistics Data Reset, 2 = Device Temperature Reset, 4 = Power Supply Voltage Reset, 5 = Operation Time Reset, 12 = SSC1 Switch Counts Reset, 13 = SSC2 Switch Counts Reset, 15 = SSC4 Switch Counts Reset, 16 = Distance Resetable Histogram Reset, 48 = Standard Profile, 49 = Fast Profile, 50 = Long Range Profile, 84 = Teach Analog Corner 1., 85 = Teach Analog Corner 2., 255 = Alignment Assistance
access rights: wo
modifies other variables

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "SSC.4 Param" index=16386 id=V_SSP_SSC04_Param

description: Defines the setpoint values for switching signal channel 4.
data type: 64-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 32 32-bit Integer 0..60000 10 SP1 Defines the setpoint 1 value for the switching signal channel.
2 0 32-bit Integer 0..60000 50 SP2 Defines the setpoint 2 value for the switching signal channel.

octet 0 1 2 3 4 5 6 7
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "SSC.4 Config" index=16387 id=V_SSP_SSC04_Config

description: Defines the configuration parameter for switching signal channel 4.
data type: 16-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 8 8-bit UInteger 0 = High active, 1 = Low active 0 Logic Defines the logical representation of the switching signal SSC in the process data.
2 0 8-bit UInteger 0 = Deactivated, 1 = Single point, 2 = Window 0 Mode Defines the evaluation mode for the switching signal SSC.

octet 0 1  
bit offset 15 - 8 7 - 0  
subindex 1 2  
element bit 7 - 0 7 - 0  

Variable "MDC1 Descriptor" index=16512 id=V_MdcDescriptor

description: Descriptor for the characteristic of the measurement data channel 1 (process data MV).
data type: 88-bit Record (subindex access not supported)
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 56 32-bit Integer 100 Lower Limit Shows the lower value of measurement range.
2 24 32-bit Integer 2700 Upper Limit Shows the upper value of measurement range.
3 8 16-bit UInteger 1010 = Meter, 1342 = %, 1997 = None 1010 Unit Code Shows the unique code for the physical unit.
4 0 8-bit Integer -3 Scale Shows the multiplier for measurement value - 10exp(scale).

octet 0 1 2 3 4 5 6 7
bit offset 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10  
bit offset 23 - 16 15 - 8 7 - 0  
subindex 3 3 4  
element bit 15 - 8 7 - 0 7 - 0  

Events

CodeTypeNameDescription
16912 (0x4210)WarningDevice temperature overrunClear source of heat
20480 (0x5000)ErrorDevice hardware faultExchange device
20752 (0x5110)WarningPrimary supply voltage overrunCheck valid voltage range
20753 (0x5111)WarningPrimary supply voltage underrunCheck valid voltage range
30480 (0x7710)ErrorShort circuitCheck installation
35904 (0x8c40)WarningMaintenance required - CleaningClean device

Process Data Formatting

Formatting for Process Data id=PI_ProcessDataInDistance
Subindex 1: mm
Subindex 3:
Subindex 4:
Subindex 5:
Subindex 6:
Subindex 7:

Formatting for Process Data id=PO_ProcessDataOutDistance
Subindex 1:
Subindex 2:

Formatting for Process Data id=PI_ProcessDataInQuality
Subindex 1: %
Subindex 3:
Subindex 4:
Subindex 5:
Subindex 6:
Subindex 7:

Formatting for Process Data id=PO_ProcessDataOutQuality
Subindex 1:
Subindex 2:

Formatting for Process Data id=PI_ProcessDataInCounterSSC1
Subindex 1:
Subindex 3:
Subindex 4:
Subindex 5:
Subindex 6:
Subindex 7:

Formatting for Process Data id=PO_ProcessDataOutCounterSSC1
Subindex 1:
Subindex 2:

Formatting for Process Data id=PI_ProcessDataInCounterSSC2
Subindex 1:
Subindex 3:
Subindex 4:
Subindex 5:
Subindex 6:
Subindex 7:

Formatting for Process Data id=PO_ProcessDataOutCounterSSC2
Subindex 1:
Subindex 2:

Formatting for Process Data id=PI_ProcessDataInCounterSSC4
Subindex 1:
Subindex 3:
Subindex 4:
Subindex 5:
Subindex 6:
Subindex 7:

Formatting for Process Data id=PO_ProcessDataOutCounterSSC4
Subindex 1:
Subindex 2:

Operator Menus

Identification Menu
V_VendorName
V_VendorText
V_ProductName
V_ProductID
V_ProductText
V_ApplicationSpecificTag
V_CP_FunctionTag
V_CP_LocationTag
V_SerialNumber
V_FirmwareRevision
V_HardwareRevision

Parameters Menu
MDC Configuration
V_MDCSelection.Source, ro

Maintenance Menus

Identification Menu
V_VendorName
V_VendorText
V_ProductName
V_ProductID
V_ProductText
V_ApplicationSpecificTag
V_CP_FunctionTag
V_CP_LocationTag
V_SerialNumber
V_FirmwareRevision
V_HardwareRevision

Parameters Menu
System Commands
V_SystemCommand, Button:=128
Description=A warm start is triggered and the device will be set to an initial state. The communication will be interrupted by the device and then reinitiated by the master.
V_SystemCommand, Button:=129
Description=The parameter of the technology-specific application are set to default values. Identification parameter remain unchanged. An upload to the data storage of the master will be executed, if activated in the port configuration of the master.
V_SystemCommand, Button:=130
Description=The parameter of the device are reset to factory settings. Note: A download of the data storage may be executed on the next power cycle and overwrite the factory default settings!
V_SystemCommand, Button:=131
Description=The parameter of the device are set to factory default values and communication will be inhibited until the next power cycle. Note: Directly detach the device from the master port!
V_BaumerCommands, Button:=255
Description=Activate alignment assistance (increased laser brightness)
Measurement Values
V_MeasurementValues.Distance mm
V_MeasurementValues.Counter Value
Switch Counts
V_BaumerCommands, Button:=12
V_BaumerCommands, Button:=13
V_BaumerCommands, Button:=15
V_SSCSwitchCounts
MDC Configuration
V_MDCSelection.Source
MDC Descriptor
V_MdcDescriptor
SSC1 Configuration
Setpoints
V_SSP_SSC01_Param.SP1 mm
V_SSP_SSC01_Param.SP2 mm
Config
V_SSP_SSC01_Config.Logic, rw
V_SSP_SSC01_Config.Mode, rw
V_SSP_SSC01_Config.Hyst, ro
V_SSC_HysteresisSettings.SSC1 Alignment, rw
Timefilter
V_SSC_ReleaseDelay.SSC1 Time ms, rw
V_SSC_ResponseDelay.SSC1 Time ms, rw
V_SSC_MinPulseDuration.SSC1 Time ms, rw
V_SSC_MinPulseDuration.SSC1 Mode, rw
SSC2 Configuration
Setpoints
V_SSP_SSC02_Param.SP1 mm
V_SSP_SSC02_Param.SP2 mm
Config
V_SSP_SSC02_Config.Logic, rw
V_SSP_SSC02_Config.Mode, rw
V_SSP_SSC02_Config.Hyst, ro
V_SSC_HysteresisSettings.SSC2 Alignment, rw
Timefilter
V_SSC_ReleaseDelay.SSC2 Time ms, rw
V_SSC_ResponseDelay.SSC2 Time ms, rw
V_SSC_MinPulseDuration.SSC2 Time ms, rw
V_SSC_MinPulseDuration.SSC2 Mode, rw
SSC4 Configuration
Setpoints
V_SSP_SSC04_Param.SP1, rw
V_SSP_SSC04_Param.SP2, rw
Config
V_SSP_SSC04_Config
V_SSC_SourceSettings.SSC4 Source Selection, rw
V_SSC_SourceSettings.SSC4 Auto Reset, rw
Timefilter
V_SSC_ReleaseDelay.SSC4 Time ms, rw
V_SSC_ResponseDelay.SSC4 Time ms, rw
V_SSC_MinPulseDuration.SSC4 Time ms, rw
V_SSC_MinPulseDuration.SSC4 Mode, rw
Teach
Teach Point Offset
V_SwitchpointSettings.Teachpoint Offset.SSC1 %
V_SwitchpointSettings.Teachpoint Offset.SSC2 %
Teach Single Value
V_SSP_TeachSelect
V_SystemCommand, Button:=65
Description=Determine setpoint 1 in an single teach procedure.
V_SystemCommand, Button:=66
Description=Determine setpoint 2 in an single teach procedure.
V_SSP_TeachResult.State
Teach Two Value
V_SSP_TeachSelect
V_SystemCommand, Button:=67
Description=Determine teachpoint 1 for setpoint 1.
V_SystemCommand, Button:=68
Description=Determine teachpoint 2 for setpoint 1.
V_SystemCommand, Button:=69
Description=Determine teachpoint 2 for setpoint 2.
V_SystemCommand, Button:=70
Description=Determine teachpoint 2 for setpoint 2.
V_SystemCommand, Button:=64
Description=Calculate and apply setpoint.
V_SystemCommand, Button:=79
Description=Cancel ongoing teach procedure.
V_SSP_TeachResult.Flag SP1 TP1
V_SSP_TeachResult.Flag SP1 TP2
V_SSP_TeachResult.Flag SP2 TP1
V_SSP_TeachResult.Flag SP2 TP2
V_SSP_TeachResult.State
Teach Dynamic
V_SSP_TeachSelect
V_SystemCommand, Button:=71
Description=Start dynamic teach for setpoint 1.
V_SystemCommand, Button:=72
Description=Stop dynamic teach for setpoint 1.
V_SystemCommand, Button:=73
Description=Start dynamic teach for setpoint 2.
V_SystemCommand, Button:=74
Description=Stop dynamic teach for setpoint 2.
V_SystemCommand, Button:=79
Description=Cancel ongoing teach procedure.
V_SSP_TeachResult.State
Teach Analog
V_BaumerCommands, Button:=84
Description=Teach distance for corner point 1
V_BaumerCommands, Button:=85
Description=Teach distance for corner point 2
Signal Processing
V_BaumerCommands, Button:=48
Description=Change Settings to standard profile
V_BaumerCommands, Button:=49
Description=Change Settings to fast profile
V_BaumerCommands, Button:=50
Description=Change Settings to long range profile
V_ConfigurationProfiles
Expert
V_OperationModes
V_PV_DisruptionFilter.Maximum perturbation time ms
V_PV_DisruptionFilter.Distance mm
V_PV_ExponentialFilter.Smoothing Factor ms
Temperature Settings
V_UnitSelection
Local User Interface
V_TeachModeSettings
V_TeachLockSettings.qTeach Time Out min
V_LedSettings
Quality Parameters
V_QualityValue.Value %
V_QualityBitThreshold.Threshold %
Device Access Locks
V_DeviceAccessLocks.Local Parameterization

Diagnosis Menu
V_DeviceStatus
Detailed Device Status
V_DetailedDeviceStatus
System Commands
V_BaumerCommands, Button:=1
Device Temperature
V_BaumerCommands, Button:=2
V_DeviceTemperature.Current, Dec.2
V_DeviceTemperature.Resetable Min, Dec.2
V_DeviceTemperature.Resetable Max, Dec.2
V_DeviceTemperature.Lifetime Min, Dec.2
V_DeviceTemperature.Lifetime Max, Dec.2
V_UnitSelection.Temperature, ro
Power Supply
V_BaumerCommands, Button:=4
V_PowerSupplyVoltage.Current V, Dec.2
V_PowerSupplyVoltage.Resetable Min V, Dec.2
V_PowerSupplyVoltage.Resetable Max V, Dec.2
V_PowerSupplyVoltage.Lifetime Min V, Dec.2
V_PowerSupplyVoltage.Lifetime Max V, Dec.2
Bootcycles
V_Bootcycles
Operation Time
V_BaumerCommands, Button:=5
V_OperationTime.Powerup "
V_OperationTime.Resetable "
V_OperationTime.Lifetime "
Histogram
Device Temperature
V_DeviceTemperatureLifetimeHistogram
Power Supply
V_PowerSupplyVoltageLifetimeHistogram
Distance
V_BaumerCommands, Button:=16
V_ProcessValue1ResetableHistogram

Commissioning Menus

Identification Menu
V_VendorName
V_VendorText
V_ProductName
V_ProductID
V_ProductText
V_ApplicationSpecificTag
V_CP_FunctionTag
V_CP_LocationTag
V_SerialNumber
V_FirmwareRevision
V_HardwareRevision

Parameters Menu
System Commands
V_SystemCommand, Button:=128
Description=A warm start is triggered and the device will be set to an initial state. The communication will be interrupted by the device and then reinitiated by the master.
V_SystemCommand, Button:=129
Description=The parameter of the technology-specific application are set to default values. Identification parameter remain unchanged. An upload to the data storage of the master will be executed, if activated in the port configuration of the master.
V_SystemCommand, Button:=130
Description=The parameter of the device are reset to factory settings. Note: A download of the data storage may be executed on the next power cycle and overwrite the factory default settings!
V_SystemCommand, Button:=131
Description=The parameter of the device are set to factory default values and communication will be inhibited until the next power cycle. Note: Directly detach the device from the master port!
V_BaumerCommands, Button:=255
Description=Activate alignment assistance (increased laser brightness)
Measurement Values
V_MeasurementValues.Distance mm
V_MeasurementValues.Counter Value
Switch Counts
V_BaumerCommands, Button:=12
V_BaumerCommands, Button:=13
V_BaumerCommands, Button:=15
V_SSCSwitchCounts
MDC Configuration
V_MDCSelection.Source
MDC Descriptor
V_MdcDescriptor
SSC1 Configuration
Setpoints
V_SSP_SSC01_Param.SP1 mm
V_SSP_SSC01_Param.SP2 mm
Config
V_SSP_SSC01_Config.Logic, rw
V_SSP_SSC01_Config.Mode, rw
V_SSP_SSC01_Config.Hyst, ro
V_SSC_HysteresisSettings.SSC1 Alignment, rw
Timefilter
V_SSC_ReleaseDelay.SSC1 Time ms, rw
V_SSC_ResponseDelay.SSC1 Time ms, rw
V_SSC_MinPulseDuration.SSC1 Time ms, rw
V_SSC_MinPulseDuration.SSC1 Mode, rw
SSC2 Configuration
Setpoints
V_SSP_SSC02_Param.SP1 mm
V_SSP_SSC02_Param.SP2 mm
Config
V_SSP_SSC02_Config.Logic, rw
V_SSP_SSC02_Config.Mode, rw
V_SSP_SSC02_Config.Hyst, ro
V_SSC_HysteresisSettings.SSC2 Alignment, rw
Timefilter
V_SSC_ReleaseDelay.SSC2 Time ms, rw
V_SSC_ResponseDelay.SSC2 Time ms, rw
V_SSC_MinPulseDuration.SSC2 Time ms, rw
V_SSC_MinPulseDuration.SSC2 Mode, rw
SSC4 Configuration
Setpoints
V_SSP_SSC04_Param.SP1, rw
V_SSP_SSC04_Param.SP2, rw
Config
V_SSP_SSC04_Config
V_SSC_SourceSettings.SSC4 Source Selection, rw
V_SSC_SourceSettings.SSC4 Auto Reset, rw
Timefilter
V_SSC_ReleaseDelay.SSC4 Time ms, rw
V_SSC_ResponseDelay.SSC4 Time ms, rw
V_SSC_MinPulseDuration.SSC4 Time ms, rw
V_SSC_MinPulseDuration.SSC4 Mode, rw
Teach
Teach Point Offset
V_SwitchpointSettings.Teachpoint Offset.SSC1 %
V_SwitchpointSettings.Teachpoint Offset.SSC2 %
Teach Single Value
V_SSP_TeachSelect
V_SystemCommand, Button:=65
Description=Determine setpoint 1 in an single teach procedure.
V_SystemCommand, Button:=66
Description=Determine setpoint 2 in an single teach procedure.
V_SSP_TeachResult.State
Teach Two Value
V_SSP_TeachSelect
V_SystemCommand, Button:=67
Description=Determine teachpoint 1 for setpoint 1.
V_SystemCommand, Button:=68
Description=Determine teachpoint 2 for setpoint 1.
V_SystemCommand, Button:=69
Description=Determine teachpoint 2 for setpoint 2.
V_SystemCommand, Button:=70
Description=Determine teachpoint 2 for setpoint 2.
V_SystemCommand, Button:=64
Description=Calculate and apply setpoint.
V_SystemCommand, Button:=79
Description=Cancel ongoing teach procedure.
V_SSP_TeachResult.Flag SP1 TP1
V_SSP_TeachResult.Flag SP1 TP2
V_SSP_TeachResult.Flag SP2 TP1
V_SSP_TeachResult.Flag SP2 TP2
V_SSP_TeachResult.State
Teach Dynamic
V_SSP_TeachSelect
V_SystemCommand, Button:=71
Description=Start dynamic teach for setpoint 1.
V_SystemCommand, Button:=72
Description=Stop dynamic teach for setpoint 1.
V_SystemCommand, Button:=73
Description=Start dynamic teach for setpoint 2.
V_SystemCommand, Button:=74
Description=Stop dynamic teach for setpoint 2.
V_SystemCommand, Button:=79
Description=Cancel ongoing teach procedure.
V_SSP_TeachResult.State
Teach Analog
V_BaumerCommands, Button:=84
Description=Teach distance for corner point 1
V_BaumerCommands, Button:=85
Description=Teach distance for corner point 2
Signal Processing
V_BaumerCommands, Button:=48
Description=Change Settings to standard profile
V_BaumerCommands, Button:=49
Description=Change Settings to fast profile
V_BaumerCommands, Button:=50
Description=Change Settings to long range profile
V_ConfigurationProfiles
Expert
V_OperationModes
V_PV_DisruptionFilter.Maximum perturbation time ms
V_PV_DisruptionFilter.Distance mm
V_PV_ExponentialFilter.Smoothing Factor ms
Temperature Settings
V_UnitSelection
Input/Output Settings
V_DIDOSettings
Analog Output
V_Output_2PointScaler.Corner 1 Input mm
V_Output_2PointScaler.Corner 1 Output * 0.1 mA
V_Output_2PointScaler.Corner 2 Input mm
V_Output_2PointScaler.Corner 2 Output * 0.1 mA
V_AnalogOutputSettings.Analog Alarm Mode
Local User Interface
V_TeachModeSettings
V_TeachLockSettings.qTeach Time Out min
V_LedSettings
Quality Parameters
V_QualityValue.Value %
V_QualityBitThreshold.Threshold %
Device Access Locks
V_DeviceAccessLocks.Local Parameterization

Diagnosis Menu
V_DeviceStatus
Detailed Device Status
V_DetailedDeviceStatus
System Commands
V_BaumerCommands, Button:=1
Device Temperature
V_BaumerCommands, Button:=2
V_DeviceTemperature.Current, Dec.2
V_DeviceTemperature.Resetable Min, Dec.2
V_DeviceTemperature.Resetable Max, Dec.2
V_DeviceTemperature.Lifetime Min, Dec.2
V_DeviceTemperature.Lifetime Max, Dec.2
V_UnitSelection.Temperature, ro
Power Supply
V_BaumerCommands, Button:=4
V_PowerSupplyVoltage.Current V, Dec.2
V_PowerSupplyVoltage.Resetable Min V, Dec.2
V_PowerSupplyVoltage.Resetable Max V, Dec.2
V_PowerSupplyVoltage.Lifetime Min V, Dec.2
V_PowerSupplyVoltage.Lifetime Max V, Dec.2
Bootcycles
V_Bootcycles
Operation Time
V_BaumerCommands, Button:=5
V_OperationTime.Powerup "
V_OperationTime.Resetable "
V_OperationTime.Lifetime "
Histogram
Device Temperature
V_DeviceTemperatureLifetimeHistogram
Power Supply
V_PowerSupplyVoltageLifetimeHistogram
Distance
V_BaumerCommands, Button:=16
V_ProcessValue1ResetableHistogram

Note: This page shows the content of an IODD file transformed into HTML format. In the case of disparity between this and the XML view, the content of the XML file takes precedence.
Created by IODD Viewer V1.2.